Hitachi
Modelo Defeito Solução
CM2188 Morto.Nao liga. Troque STR84145 e fusivel 120V Troque 220V FUSE.
HM-4119D Linha Vertical na Tela. Verificar Q204, T201, L1, L202, L201.
HM-4119D Fonte parada - Fusível está ok. Verifique: FR100, R150, ZD100, SP12, PHC1, PHC11, ZD101, D9, Q4, Q5, Q100, Q101.
HM-4119D Fonte parada - Fusível queimado Verifique: D100, C103, C104, R100, R102, C105, D101, Q100, Q101, IC2, Q6, Q7, C13.
HM-4119D No framing. Check of IC301.
HM-4119D The pictures in up and bottom is bad. Check of C306-C308, C301.
HM-4119D Linha Horizontal na Tela. Check of C308, R316, R305, C306, IC300.
HM-4119D No synchronizing on lines. Check of IC200.
HM-4119D The size of raster is bad. Check of IC201, Q202, Q203, Q209.
HM-4119D Vertical line. Check of Q204, T201, L1, L202, L201.
HM-4119D Sem imagem ,proteçao da fonte atuando. Check of Q200-Q204, Q206, D204, C204, C206, T202, C209.
HM-4119D Output voltage of power supply is not good. Check ZD10, PCH11, PCH1, Q6, Q7.
HM-4119D Monitor não liga - Fusível Ok. Check FR100, R150, ZD100, SP12, PHC1, PHC11, ZD101, D9, Q4, Q5, Q100, Q101.
HM-4119D Monitor com fusível queimado. Check of D100, C103, C104, R100, R102, C105, D101, Q100, Q101, IC2, Q6, Q7, C13.

Clique aqui Coletânea de  defeitos

colabore mande sua dica p/  BANCO DE DEFEITOS